TnP-500 Test n Print Instrument
+ Freight and GST
Model TNP-500
Product Description
The TNP-500, Fully automated test n print unit consists of:
A fully integrated unit @ 10 Amp operation
Has all the functions of the TNT +M
Scanner
Keyboard
Wavecom (barcode) thermal transfer Printer
5000 item memory
WinPATS Premium software
Optional Isolation transformer available
Hard Transit Carry Case Large, manufactured from ultra high impact structural polymer
Custom configured Tags (1000 Standard white labels)
12 month calibration certificate
12 months warranty
Fully Australian designed and manufactured
|
||
|
Mains Supply Tests |
Checks Polarity and continuity of mains supply by LED indicators (A-N, A-E, and N-E). (Flashing red LED indicates test fail) |
|
Class I Tests- Earthed Appliance |
Appliance Check: Ensures appliance is plugged in and turned on. |
|
Class II Tests - Double Insulated Appliance |
Appliance Check: Ensures appliance is plugged in and turned on. |
|
Extension Lead Tests |
Earth Bond Test: 200mA test current. Pass level Less than 1Ω. Measurement: 0.01Ω to 10.0Ωs Insulation Test: 500VDC / 250VDC. Pass level Greater than 1MΩ. Measurement: 0.1Ω to 10.0MΩ. Continuity/Polarity Test: 250VAC check continuity and polarity of leads. Displays Pass/Fail |
|
Power Measurement |
Leakage Current: 0 to 30.0mA at 200 to 265V Load Current: 0.0 to 10Amp (20Amp for TnP-500X) Voltage: 200 to 265VAC - Power Factor: 0.00 to 1.00 Apparent Power: 0 to 2400VA -Power 0 to 2400W |
|
Meter Mode® |
Green ashing LED denotes Meter Mode is engaged Load Current: 0.0 to 10Amp |
|
RCD Tests |
Trip Current: 2 to 500mA in 1mA steps - User selectable. Trip Time: 0 to 3,000ms at .001sec resolution. Current Ramp Trip Test: 0 to 500mA in 1mA increments. |
|
Leakage Tests |
Leakage Current: 0 to 30.0mA at 200 to 265V |
|
Memory |
5000 Items - 20,000 item upgrade optional |
|
Battery |
6700 mAH, 98WH, Charge Time Around 4 Hours |
| Brochure |
|---|