TSI Pan 341 Air Duct Leak Tester

Contact Us for Price

AS 4254.2:2012 mandates leakage testing of systems over 3000 L/s. As this standard has been incorporated into the 2013 National Construction Code, leakage testing has become a legal requirement for all such systems from the 1st May 2013. Managing duct leakage can have a significant effect on HVAC system performance, energy consumption and greenhouse gas emissions. The TSI PANDA 341 will allow you to confirm the quality of the HVAC duct system.

EAN: N/A SKU: TSIPan341 TSI Pan 341 Air Duct Leak Tester Category:
  • TSI PAN 341
  • testinstruments.net.au
  • HVAC duct system
  • quantify air leakage in ductwork

 

AS 4254.2:2012 mandates leakage testing of systems over 3000 L/s. As this standard has been incorporated into the 2013 National Construction Code, leakage testing has become a legal requirement for all such systems from the 1st May 2013.

Managing duct leakage can have a significant effect on HVAC system performance, energy consumption and greenhouse gas emissions.

 

 The TSI PANDA 341 will allow you to confirm the quality of the HVAC duct system.

 

Product Details: The Airflow Positive and Negative Duct Accreditation (PANDA) System provides contractors, commissioning engineers, and research and development technicians with the best in class choice of test equipment to quantify air leakage in ductwork and other areas as well as the ability to measure the performance of ducted systems. The PANDA provides a fast, accurate, automated solution and helps to ensure compliance with EN12237, EN1507 and EUROVENT 2/2 and SMACNAstandards, enhancing energy savings in buildings. Positive and Negative Duct Leakage Testing in one rig Energy savings by testing and minimizing duct leaks Compliant with the following standards: EN12237 Ventilation for Buildings—Ductwork—Strength & Leakage of Circular Sheet Metal Ducts EN1507 Ventilation for Buildings—Sheet Metal ducts with Rectangular Section—Requirements for Strength and Leakage EUROVENT 2/2 Air Leakage Rate in Sheet Metal Air Distribution Systems SMACNA Air Duct Leakage Testing Accuracy is ± 2,5% of volume flow Unique performance and fan speed control charge up of duct system to test static pressure within minutes Fits in the back of vans and estate cars Model PAN341 comes with standard Airflow TA465-P Multi-Function Instrument and PVM620 Micromanometer. Automatically calculates leakage rate in real time Simultaneous displays flow leakage rate and static pressure Provides a pass/fail indication for a given tightness class Automatically corrects actual volume flow leakage rate to Standard Temperature and Pressure (STP) Monitors barometric pressure and temperature in real time Stores data that can be downloaded for report generation and documentation Works with Model 8934 Portable Printer

Shopping Cart
Scroll to Top